Knowledge Base › Structural Design Error Case Study › Air Compressor Outlet Pipe Gas Pulsation

Air Compressor Outlet Pipe Gas Pulsation

E42-363 · Vibration and Resonance · Screw Air Compressor Discharge Pipe · ★★

Problem Description

Screw air compressor discharge pipe (Φ80) gas pulsation breaks bracket by vibration; 2 shutdowns per month

Root Cause

[Pulsation] Discharge pulse frequency f=2×n coincides with pipe natural frequency; gas column resonance.
[Fracture] Bracket stress exceeds; weld cracks.
[Design Omission] No buffer tank; no gas column analysis; safety factor 1.2.

Corrective Solution

1) Install buffer tank at outlet, volume ≥0.3m³;
2) Add damping rubber to pipe clamps;
3) Detune gas column frequency by ≥25%;
4) Enlarge pipe diameter to lower velocity;
5) Measure pulsation each batch;
6) Densify brackets;
7) Limit discharge pressure;
8) Periodic NDE.

Checklist

Reference

GB/T 13279-2015