E42-369 · Vibration and Resonance · LS400 Screw Conveyor · ★★
LS400 screw conveyor at hanger bearing amplitude 8mm; hanger rod fractures; 2 shutdowns per month
[Resonance] Hanger rod natural f=11Hz coincides with screw rotational frequency 11.4Hz.
[Rod Fracture] Amplified alternating stress.
[Design Omission] Hanger spacing too large; no frequency avoidance; safety factor 1.2.
1) Reduce hanger spacing from 3m to 2m;
2) Enlarge hanger rod to raise natural frequency;
3) Detune frequency by ≥25%;
4) Add rubber vibration isolation;
5) Measure vibration each batch;
6) Flaw-detect hanger rods;
7) Limit speed;
8) Periodic patrol.
JB/T 7679-2008