E42-370 · Vibration and Resonance · 5m³ Reactor Agitator Shaft · ★★

Problem Description

5m³ reactor agitator shaft (length 2800mm) lateral swing 5mm; shaft seal leaks; 2 repairs per month

Root Cause

[Lateral Vibration] Shaft slenderness ratio L/d=47 exceeds critical; first-order critical low.
[Leakage] Large swing; mechanical seal damaged.
[Design Omission] No intermediate bearing; diameter too small; safety factor 1.2.

Corrective Solution

1) Add intermediate bearing to shaft;
2) Increase shaft diameter from 60 to 80mm;
3) Detune first-order critical by ≥20%;
4) Change mechanical seal to double-end face;
5) Measure swing each batch;
6) Dynamic balance;
7) Limit agitation speed;
8) Periodic seal replacement.

Checklist

Reference

HG/T 20569-2013