E42-454 · Vibration and Resonance · Centrifugal Compressor Piping · ★★

Problem Description

Centrifugal compressor (outlet DN300) piping pulsation pressure ±0.08MPa; piping amplitude 1.2mm resonance abnormal noise; cracks once a month

Root Cause

[Gas Pulsation] Impeller passing frequency f=85Hz resonates with pipe length λ; pulsation pressure amplitude 0.08MPa.
[Resonance] Pipe natural 85Hz coincides and amplifies.
[Design Omission] No buffer tank; supports/suspensions not modified; safety factor 1.4 (should be ≥2.0).

Corrective Solution

1) Add buffer tank at outlet (0.5m³);
2) Detune support/suspension frequency by ≥30%;
3) Add pulsation attenuator;
4) Add damping to pipe clamps;
5) Measure vibration monthly;
6) Limit speed to avoid;
7) Weld seam flaw detection;
8) Periodic re-measurement.

Checklist

Reference

GB/T 20801.3-2006