Knowledge Base › Structural Design Error Case Study › Flange Disc Radial Fatigue Crack

Flange Disc Radial Fatigue Crack

E42-376 · Fatigue Fracture · Pressure Vessel Flange · ★★

Problem Description

Pressure vessel flange (Φ600) radial crack between bolt holes; leaks; 1 repair per month

Root Cause

[Ligament] Bolt hole ligament width only 12mm; stress concentration.
[Fatigue] Alternating σ=200MPa; life 4×10⁶ cycles (design ≥1×10⁷).
[Design Omission] Ligament too narrow; not chamfered; safety factor 1.3.

Corrective Solution

1) Raise ligament width to 18mm;
2) Hole mouth chamfer R2;
3) Thicken flange;
4) Fatigue check;
5) Magnetic particle test each batch;
6) Uniform preload;
7) Pressure limit;
8) Periodic NDE.

Checklist

Reference

GB/T 150.3-2011