E42-509 · Fatigue Fracture · Hot Die Forging Press (1600t) · ★★★
Connecting rod bolt M48; insufficient preload σa=180MPa; fractures at 5×10^5 cycles; 2 shutdowns per month
[Bolt Fatigue] σa=180MPa; thread stress concentration Kt=3; Goodman n=0.95<1.
[Low Preload] Insufficient torque; no anti-loosening.
[Design Omission] No bolt fatigue check; torque not controlled; safety factor 1.0 (should be ≥1.5).
1) Change bolt to fine thread M48×3;
2) Control torque to ±5%;
3) Add anti-loosening nylon insert;
4) Check loosening each shift;
5) Limit tonnage to ≤1500;
6) Flaw detect bolt;
7) Upgrade strength to grade 10.9;
8) Periodic preload recheck.
GB/T 3098.1-2010