E42-062 · Weld Distortion & Defects · Bracket Fillet Weld Q235 · ★★

Problem Symptom

Weld leg 5mm (8mm required), tearing under load

Root Cause

[Fillet Load Capacity] With leg size a=5mm, throat thickness 0.7a=3.5mm and length l=100mm, the load capacity is P=0.7a·l·τ=3.5×100×160=56000N, while 84000N is required, a 33% shortfall.
[Tearing] The actual stress exceeds the allowable by 33%, and tearing occurs under dynamic loading.
[Design Omission] The drawing called for a=8 but this was not followed and no weld gauge sampling was done, so the weld cracked.

Correct Solution

1) Build up the weld leg to a=8;
2) Sample-check the weld with a weld gauge every shift;
3) Check the fillet weld strength;
4) Clean the bevel before welding;
5) Use step-back welding in segments to reduce distortion;
6) Carry out a load test;
7) Standardise the welding parameters;
8) Include the weld leg dimension in the dedicated inspection.