Loss of Control of Interpass Temperature Causes Hydrogen-Induced Delayed Cracking in a Pressure Vessel

E42-061 · Weld Distortion & Defects · Pressure Vessel Shell 16MnR · ★★★

Problem Symptom

A through-wall crack was found 48h after welding

Root Cause

[Diffusible Hydrogen] The electrodes were not baked and contained moisture, so the weld pool [H]=12ml/100g, and as the interpass temperature fell to 80℃ the hydrogen accumulated.
[Delayed Cracking] Restraint stress, hardened structure and hydrogen combined, and the crack started 48h after welding with an unacceptable CTOD.
[Design Omission] The electrodes were not baked at 350℃ and the interpass temperature was not held at ≥120℃.

Correct Solution

1) Bake the electrodes at 350℃×1h;
2) Control the interpass temperature at ≥120℃;
3) Preheat to 100℃ before welding;
4) Dehydrogenate after welding at 250℃×2h;
5) Perform CTOD and UT inspection;
6) Use low-hydrogen electrodes;
7) Calculate the restraint rigidity;
8) Write hydrogen control into the WPS.

Checklist

References

JB/T 4709-2007 Welding Code for Steel Pressure Vessels