E42-269 · Welding Deformation and Defects · Steel Girder Butt Weld · ★★
Steel girder butt weld arc-start end pores, shrinkage cavities and lack of fusion 2mm deep; 6 spots reworked per month
[No Run-On Tab] Arc started directly on workpiece; unstable current establishment forms gas pockets and shrinkage cavities.
[Lack of Fusion] Arc-start end cools fast; insufficient penetration; 2mm deep lack of fusion becomes crack source.
[Design Omission] No run-on tab per code; end not cut and ground after welding; safety factor 1.3 (should be ≥1.8).
1) Add run-on tabs 50mm long both ends, same material and thickness;
2) Cut off and grind run-on tabs after welding;
3) RT inspect arc-start end;
4) Specify ramp-up arc-start current;
5) First-piece flaw detection each batch;
6) Keep welding wire clean and dry;
7) Clean groove to metallic luster;
8) Add run-off tab at end to prevent shrinkage cavity.
GB/T 3323-2005