Knowledge Base › Structural Design Error Case Study › Truss Gusset Plate Lack of Fusion

Truss Gusset Plate Lack of Fusion

E42-386 · Welding Deformation and Defects · Steel Pipe Truss Joint · ★★★

Problem Description

Steel pipe truss gusset plate lack of fusion 4mm deep; joint loose; 1 spot repaired per month

Root Cause

[Lack of Fusion] Small groove angle; low heat input; 4mm deep lack of fusion.
[Loose] Joint force transfer fails.
[Design Omission] Groove design wrong; no root gouging; safety factor 1.4.

Corrective Solution

1) Machine double-sided groove on gusset plate;
2) Gouge root and weld through-penetration;
3) Control heat input to mid-value;
4) UT inspection;
5) Inspect fusion per joint;
6) Reinforce with stiffener;
7) Post-weld annealing;
8) Load test.

Checklist

Reference

GB 50017-2017

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »