📚 Technical Articles

No Anti-Loosening Measure Causes a Vibration-Excited Connection to Come Apart

E42-019 · Threaded Connection Loosening · Vibrating Screen Fastening Bolt · ★★★

Problem Symptom

30% of the bolts loosened within 1 week of running and a component fell off

Root Cause

[Loosening Mechanism] With transverse vibration amplitude a=2mm and frequency f=25Hz, self-locking of the thread pair is defeated by the friction angle β, and each week the bolt backs off 0.02 of a turn.
[Preload Decay] The preload falls from F0=30kN to 8kN, so the clamping force is insufficient.
[Design Omission] No anti-loosening device was used (a spring washer plus Loctite should be fitted) and the component fell off.

Correct Solution

1) Add a spring washer plus a double nut for anti-loosening;
2) Apply Loctite 243 thread-locking adhesive;
3) Use lock nuts with nylon inserts;
4) Set the preload in accordance with VDI 2230;
5) Tighten with a torque wrench;
6) Add witness marks for point-by-point inspection;
7) Establish a periodic re-tightening regime;
8) Include anti-loosening verification for vibration duty in the connection design check.

Checklist

References

GB/T 3098 Mechanical Properties of Fasteners