Wrong Use of Fine-Thread Bolts on a Vibrating Screen Causes Self-Loosening and Dropout

E42-071 · Threaded Connection Loosening · Vibrating Screen Fastening M16 · ★★

Problem Symptom

Fine-thread bolts self-loosened and fell off after 100 hours of running

Root Cause

[Self-Loosening] The small pitch of the fine thread gives weak anti-loosening, so the self-loosening rate in vibration duty is higher than with coarse threads.
[Dropout] With no anti-loosening washer the bolts came loose after 100 hours and the component fell off.
[Design Omission] Fine threads were wrongly used on a vibrating part and no locking plate was fitted, so parts dropped and the line stopped.

Correct Solution

1) Change to coarse-thread bolts for vibrating parts;
2) Add a double nut or a locking plate;
3) Add disc springs for anti-loosening;
4) Apply Loctite to the threads;
5) Tighten to a specified torque;
6) Inspect anti-loosening witness marks;
7) Upgrade the material grade;
8) Include anti-loosening in the design.

Checklist