Wrong Pipe Flange Tightening Sequence Causes Skew and Seal Leakage

E42-070 · Threaded Connection Loosening · Pipe Flange DN150 · ★★

Problem Symptom

Flange skewed by 0.3mm, seal leakage

Root Cause

[Tightening Sequence] Tightening sequentially instead of diagonally rotated the flange by 0.3mm, so the gasket was compressed unevenly.
[Leakage] The local bearing pressure was insufficient and the medium leaked at 0.6MPa.
[Design Omission] The flange was not tightened in a crossed symmetric sequence and no torque witness marks were applied, so leakage occurred.

Correct Solution

1) Tighten in a crossed diagonal sequence in 2-3 passes;
2) Select the torque according to the gasket type;
3) Check flange parallelism to ≤0.2mm;
4) Apply torque witness marks to detect missing tightening;
5) Control the gasket compression;
6) Pressure test at 0.9MPa;
7) Use bolts of equal length;
8) Include the tightening sequence in the work instruction.

Checklist

References

GB/T 9124.1-2019 Steel Pipe Flanges

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »