E42-069 · Threaded Connection Loosening · High-Temperature Flange Bolt M24 · ★★
Bolts seize on removal and the threads are torn and roughened
[Friction Coefficient] Without lubrication μ=0.2, and the frictional heat generated by the assembly torque locally welds the threads together.
[Seizure] At high temperature, oxidation plus no lubrication causes the thread pair to seize and become impossible to disassemble.
[Design Omission] Assembly was not lubricated per specification and no anti-seize agent was used, making maintenance difficult.
1) Apply a molybdenum disulfide anti-seize agent to the thread pair;
2) Lubricate and assemble in accordance with the specified torque;
3) Use nickel-based anti-galling treatment for high temperatures;
4) Calibrate the torque wrench;
5) Heat the joint to free the bolts when removing them;
6) Use high-temperature-resistant bolt material;
7) Lubricate during regular maintenance;
8) Include lubrication in the assembly process.
GB/T 3098.1-2010 Mechanical Properties of Fasteners