Overlong Studs Give Insufficient Stiffness and Relax

E42-021 · Threaded Connection Loosening · Cylinder Head Stud Bolt · ★★★

Problem Symptom

Studs elongated and relaxed after thermal cycling, causing leakage

Root Cause

[Excessive Compliance] The stud has a length L=160mm and d=12, so its compliance is δ/F=L/(EA)=160/(113×2200)=6.4e-4mm/N.
[Relaxation Amount] With a temperature difference ΔT=200℃ the stud thermally elongates by ΔL=αLΔT=2.4e-5×160×200=0.77mm, losing 40% of the preload.
[Design Omission] The studs were not shortened and no thermal compensation was provided, so thermal relaxation caused the leak.

Correct Solution

1) Shorten the shank portion of the stud to reduce compliance;
2) Use a reduced-diameter stud of equal strength;
3) Add disc springs to compensate for thermal elongation;
4) Raise the preload class;
5) Re-tighten in the hot state;
6) Calculate the stud compliance;
7) Carry out a leak test;
8) Include hot re-tightening in the high-temperature connection process.

Checklist

References

GB/T 3103 Tolerances of Fasteners