Knowledge Base › Structural Design Error Case Study › Unlubricated Thread Pair Causing Preload Decay and Loosening

Unlubricated Thread Pair Causing Preload Decay and Loosening

E42-170 · Threaded Fastener Loosening · Reactor Flange M27 Bolt · ★★

Problem Description

After heating, bolt preload drops 50% and the seal leaks.

Root Cause

[High Friction] Unlubricated thread friction coefficient μ=0.2; actual preload only 50% of design. [Decay] Thermal cycling makes preload repeatedly fluctuate and decay. [Design Omission] No molybdenum disulfide, μ not controlled; leakage.

Corrective Solution

1. Apply molybdenum disulfide to the thread pair to lower μ to 0.12.
2. Calculate preload torque from measured μ.
3. Add spiral-wound gaskets to the flange for compression.
4. Hot retighten after heating.
5. Add sleeves to bolts for uniform temperature.
6. Control sealing-face roughness to Ra1.6.
7. Pressure-hold leak detection.
8. Spot-check the flange each shift for leaks.

Checklist

Reference

GB/T 16823.2-1997

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »