E42-169 · Threaded Fastener Loosening · Conveyor M20 Bolt (Wrongly Used Coarse Thread) · ★★
After one week of operation the nut turns loose and the joint faces open.
[Wrong Pitch] Coarse thread wrongly used under dynamic load; lead is large and self-locking angle small. [Self-Loosening] The thread pair slips along the lead under vibration; preload decays 40%. [Design Omission] No fine thread + locking, no thread adhesive; 12 loosenings per month.
1. Change dynamic-load joints to fine thread.
2. Add nylon-insert lock nuts.
3. Apply anaerobic thread-locking adhesive to the thread pair.
4. Add spring washers or disc springs.
5. Recalculate preload torque for fine thread.
6. Periodically retighten and record.
7. Mark locking points at critical locations.
8. Select locking bolts for vibration zones.
GB/T 5782-2016