E42-121 · Threaded Connection Loosening · Exhaust Manifold Stainless Steel to Cast Iron Flange · ★★
The bolt preload relaxed after thermal cycling and the joint leaked gas
[Expansion Difference] The linear expansion coefficients of stainless steel and cast iron differ, so after heating the flange gap changes and the bolt is additionally elongated and relaxes.
[Relaxation] After several thermal cycles the preload falls to 50% of its initial value and the joint leaks.
[Design Omission] No disc springs were used for compensation and no hot re-tightening was performed.
1) Fit disc springs between the flanges to compensate for the relaxation;
2) Re-tighten the bolts at the working temperature;
3) Use flanges of the same material;
4) Add high-temperature anti-loosening to the bolts;
5) Carry out a hot gas tightness test on the joint;
6) Calculate and check the expansion amount;
7) Re-check the torque after 100 running hours;
8) Include thermal relaxation in high-temperature assembly.
GB/T 12777 Metal Bellows Expansion Joints