E42-231 · Threaded Fastener Loosening · Screw Jack · ★★★
Under load the screw slides down on its own, near-miss of a falling load.
[Loss of Self-Locking] Thread lead angle λ=6°> friction angle ρ=4.5°, failing self-locking condition λ<ρ. [Slip-Down Loosening] Under load the screw pair runs back on its own. [Design Omission] Standard pitch used without checking self-locking; no brake.
1. Reduce pitch so λ<4°.
2. Add a ratchet brake to prevent reverse rotation.
3. Use trapezoidal thread on the load-bearing screw.
4. Run self-locking test under load.
5. Add a torque limiter to the handle.
6. Slip-down test each batch.
7. Mark the maximum lifting capacity.
8. Brief and train on use.
GB/T 5796.1-2005