Insufficient Stud Screw-In Depth Causing Pull-Out

E42-232 · Threaded Fastener Loosening · Cylinder-Head Stud · ★★★

Problem Description

During pressure test, 2 studs pull out of the body and the cylinder head bursts open.

Root Cause

[Shallow Screw-In] Stud screw-in depth d=1.2d (should be ≥1.5d); insufficient load-bearing thread engagements. [Pull-Out] Internal thread shears and the stud pulls out. [Design Omission] Minimum screw-in used, thread load not calculated.

Corrective Solution

1. Raise screw-in depth to 1.5d.
2. Chamfer the body tapped-hole mouth.
3. Stud and nut same material to prevent galling.
4. Apply torque method for preload.
5. Stepwise pressurization in pressure test.
6. Sample-check screw-in depth each batch.
7. Calculate thread load capacity.
8. Use torque wrench in assembly.

Checklist

Reference

GB/T 897-1988

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »