E42-232 · Threaded Fastener Loosening · Cylinder-Head Stud · ★★★
During pressure test, 2 studs pull out of the body and the cylinder head bursts open.
[Shallow Screw-In] Stud screw-in depth d=1.2d (should be ≥1.5d); insufficient load-bearing thread engagements. [Pull-Out] Internal thread shears and the stud pulls out. [Design Omission] Minimum screw-in used, thread load not calculated.
1. Raise screw-in depth to 1.5d.
2. Chamfer the body tapped-hole mouth.
3. Stud and nut same material to prevent galling.
4. Apply torque method for preload.
5. Stepwise pressurization in pressure test.
6. Sample-check screw-in depth each batch.
7. Calculate thread load capacity.
8. Use torque wrench in assembly.
GB/T 897-1988