Knowledge Base › Structural Design Error Case Study › No Chamfer at Tapped-Hole Mouth Causing Bolt Off-Center Load and Bending

No Chamfer at Tapped-Hole Mouth Causing Bolt Off-Center Load and Bending

E42-235 · Threaded Fastener Loosening · Motor End-Shield Bolt Hole · ★★★

Problem Description

After assembly the bolt tilts; 2 bolts fracture under load.

Root Cause

[Sharp Edge at Hole Mouth] The tapped-hole mouth is not chamfered; the bolt head presses one side of the sharp edge, causing off-center load. [Bending Fracture] The off-center load makes bolt bending stress σ=320MPa exceed and fracture. [Design Omission] Hole mouth left as-cast, not chamfered.

Corrective Solution

1. Chamfer tapped-hole mouth C1.
2. Add flat washer under the bolt head.
3. Use end-shield spigot locating to prevent offset.
4. Tighten diagonally in three torque steps.
5. Sampling-inspect hole mouths each batch.
6. Use guide pins in assembly.
7. Upgrade bolt strength to grade 8.8.
8. Verify by force analysis.

Checklist

Reference

GB/T 196-2003

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »