E42-281 · Threaded Fastener Loosening · Equipment Fastening Bolt · ★★
Equipment fastening M16 bolts self-loosen under service vibration and the joint loosens; 20 locations retightened/replaced per month
[Pitch-Diameter Out of Tolerance] Thread pitch-diameter upper deviation +0.1mm (should be ±0.02); mesh clearance reaches 0.12mm; effective contact only 3 threads.
[Self-Loosening] The thread pair slips under vibration; axial locking torque decays 50%; the joint fails.
[Design Omission] Pitch diameter not controlled, no locking structure; safety factor 1.3 (should be ≥1.8).
1) Control thread pitch diameter to ±0.02mm;
2) Add spring washers + nylon inserts;
3) Double-nut locking;
4) Apply anaerobic locking adhesive to threads;
5) Full thread-gauge inspection each batch;
6) Verify preload ≥1.5× working load;
7) Add locking-mark structure;
8) Periodic retightening ledger.
GB/T 197-2018