E42-283 · Threaded Fastener Loosening · Stud Joint · ★★
M12 studs screwed in too deep fracture at the thread runout groove; 6 studs fracture per month
[Too Deep] Screw-in depth exceeds 2.5d; thread-end stress concentration Kt=2.8.
[Fracture] Under alternating load the runout groove σ=650MPa exceeds the fatigue limit; fracture at groove bottom.
[Design Omission] Screw-in depth not specified, no spigot stop; safety factor 1.2 (should be ≥1.8).
1) Control screw-in depth to 2~2.5d;
2) Add spigot stop;
3) Roll-stress the thread end;
4) Runout groove r≥0.5mm;
5) Check depth each batch;
6) Limit assembly torque ±10%;
7) Material re-verification;
8) Prepare assembly instructions.
GB/T 3098.1-2010