Problem Description

Flange studs (M20) fracture under alternating thermal load and the joint leaks; 6 studs replaced per month

Root Cause

[Tensile Fatigue] Alternating thermal stress σ=200MPa exceeds fatigue; cracks at thread root.
[Fracture] Breaks at the root.
[Design Omission] Preload not controlled, no locking; safety factor only 1.2.

Corrective Solution

1) Control preload to 1.5× working load;
2) Add lock nuts to studs;
3) Root fillet R≥1mm;
4) Change material to 35CrMo;
5) Magnetic-particle inspection each batch;
6) Limit temperature fluctuation;
7) Periodic re-torque;
8) Periodic replacement.