High-Temperature Bolt Relaxation and Leakage in Steam-Turbine Casing

E42-403 · Threaded Fastener Loosening · N30-8.83 Turbine HP/IP Casing · ★★★

Problem Description

N30-8.83 turbine high/intermediate-pressure casing M52 bolts relax after 8000h; steam leaks at the joint face; heat rate rises 1.2%

Root Cause

[High-Temperature Relaxation] At 520℃ bolt creep relaxation rate 0.8%/1000h; preload drops 12%. [Leakage] Insufficient joint-face specific pressure causes steam leakage. [Design Omission] No creep check, no hot-tightening compensation; safety factor 1.3 (should be ≥1.8).

Corrective Solution

1) Select grade 12.9 bolts for creep;
2) Hot-tighten by turn-of-nut to restore preload;
3) Add serrated gaskets at the joint face;
4) Insulate the casing to reduce temperature drop;
5) Retighten at each overhaul;
6) Add bolt elongation monitoring;
7) Limit operating temperature;
8) Replace at end of life.

Checklist

Reference

GB/T 12241-2005