Knowledge Base › Structural Design Error Case Study › Robot RV Reducer Bolt Loosening Causing Position Drift

Robot RV Reducer Bolt Loosening Causing Position Drift

E42-404 · Threaded Fastener Loosening · ER50 Six-Axis Robot RV Reducer · ★★

Problem Description

ER50 robot RV reducer (repeatability ±0.02) fixing M10 bolts loosen; position drifts 0.15mm beyond allowance; recalibrated 3 times per month

Root Cause

[Fretting Loosening] Frequent start/stop alternation decays preload 30%. [Drift] The reducer micro-rotates and the datum loses accuracy. [Design Omission] No thread-locking adhesive, no locating pin; safety factor 1.2 (should be ≥1.5).

Corrective Solution

1) Apply anaerobic locking adhesive to bolts;
2) Add 2 locating pins;
3) Control preload ±5%;
4) Grind flange face flat Ra0.8;
5) Spot-check each shift;
6) Add displacement sensors;
7) Limit acceleration;
8) Periodic re-torque.

Checklist

Reference

GB/T 9239.1-2006

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »