E42-466 · Threaded Fastener Loosening · Vibrating Screen Exciter · ★★
Vibrating screen (2YK1848) exciter bolts loosen and fall off; screen body cracks; repaired 3 times per month
[Vibration Loosening] Amplitude A=8mm, excitation frequency 16Hz cause bolt loosening.
[Falling Off] Insufficient preload.
[Design Omission] No locking, no vibration limit; safety factor 1.3 (should be ≥2.0).
1) Add locking disc springs;
2) Apply thread-locking adhesive;
3) Control preload to 90% of yield;
4) Add double nuts;
5) Check loosening each shift;
6) Limit amplitude;
7) Add anti-back-off tabs;
8) Periodic re-measurement.
GB/T 3098.1-2010