Knowledge Base › Structural Design Error Case Study › Insufficient Preload on Flange Joint Bolts Causing Leakage

Insufficient Preload on Flange Joint Bolts Causing Leakage

E42-467 · Threaded Fastener Loosening · Flange Joint Bolt · ★★

Problem Description

DN300 flange bolts insufficiently preloaded; interface leaks 20 drops/min; tightened 2 times per month

Root Cause

[Insufficient Preload] Torque M=200N·m low; gasket specific pressure insufficient causes leakage.
[Leakage] Interface opens.
[Design Omission] No torque method, sequence not controlled; safety factor 1.4 (should be ≥2.0).

Corrective Solution

1) Torque-method assembly M=420N·m;
2) Cross-pattern tightening;
3) Switch to spiral-wound metal gaskets;
4) Add spring washers;
5) Leak-check each shift;
6) Limit working pressure;
7) Upgrade bolt grade;
8) Periodic re-measurement.

Checklist

Reference

GB/T 9124-2010