Knowledge Base › Structural Design Error Case Study › Tensile-Loosening of Reducer Joint-Face Bolts

Tensile-Loosening of Reducer Joint-Face Bolts

E42-468 · Threaded Fastener Loosening · Reducer Joint-Face Bolt · ★★

Problem Description

Reducer (hardened-gear) joint-face bolts loosen by tension and leak oil; repaired 2 times per month

Root Cause

[Tensile Loosening] Operating temperature rise ΔT=40℃ stretches the bolt; preload drops 30% and loosens.
[Leak] Joint face opens.
[Design Omission] No temperature limit, no locking; safety factor 1.3 (should be ≥2.0).

Corrective Solution

1) Apply sealant to the joint face;
2) Add disc-spring compensation to bolts;
3) Limit operating temperature ≤70℃;
4) Torque-method assembly;
5) Leak-check each shift;
6) Add anti-back-off;
7) Upgrade bolt grade;
8) Periodic re-measurement.

Checklist

Reference

GB/T 14231-1993