Flange Bolt Loosening

E42-519 · Threaded Fastener Loosening · Pump-Body Flange (DN200) · ★★

Problem Description

Flange bolts M20 lose 40% preload under vibration and leak; tightened 3 times per month

Root Cause

[Loosening] Vibration lateral force; thread friction coefficient μ=0.12 low; preload decays.
[Poor Locking] No lock.
[Design Omission] No fine thread, no locking; safety factor 1.3 (should be ≥2.0).

Corrective Solution

1) Change to fine thread M20×1.5;
2) Add disc-spring washers;
3) Apply thread adhesive;
4) Check loosening each shift;
5) Limit vibration;
6) Control torque ±10%;
7) Diagonal tightening;
8) Periodic re-measurement.

Checklist

Reference

GB/T 196-2003

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »