E42-520 · Threaded Fastener Loosening · Reducer Base · ★★★
Anchor M24 bolts loosen under impact; body shifts 2mm; gears tooth-broken; tightened 2 times per month
[Anchor Loosening] Impact loads; uneven foundation; bolts back off.
[Low Stiffness] Thin base.
[Design Omission] No locking, thin base; safety factor 1.3 (should be ≥2.0).
1) Add lock nuts;
2) Thicken the base;
3) Grout in place;
4) Check loosening each shift;
5) Limit impact;
6) Control torque;
7) Add dowel pins;
8) Periodic re-measurement.
GB/T 196-2003