E42-521 · Threaded Fastener Loosening · Electric Motor (YS Series) · ★★
End-shield bolts M10 loosen and fracture under thermal cycling; rotor rubs; 2 motors scrapped per month
[Thermal Loosening] Thermal expansion/contraction relaxes preload; bolts fracture.
[Stress] Alternating thermal stress.
[Design Omission] No heat-resistant selection, no locking; safety factor 1.2 (should be ≥2.0).
1) Switch to heat-resistant bolts;
2) Add spring washers;
3) Control temperature rise ≤60℃;
4) Check loosening each shift;
5) Limit load;
6) Control torque;
7) Add thread adhesive;
8) Periodic re-measurement.
GB/T 196-2003