Abrupt Section Change Without Transition Causes Fracture at the Step

E42-023 · Stress Concentration · Hydraulic Cylinder Piston Rod · ★★★

Problem Symptom

Fracture at the step root, the cylinder failed

Root Cause

[Abrupt Change Stress] The diameter steps abruptly from 35 to 25 with no transition, giving Kt≈2.8 and a stress of 2.8×180=504MPa.
[Overload] 504MPa exceeds σ_s=450MPa, coupling yielding with fatigue.
[Design Omission] No taper transition was provided and no check calculation was made, so the rod broke and the cylinder failed.

Correct Solution

1) Change the step to a 1:5 taper transition;
2) Increase the fillet to R5;
3) Verify by finite element that the peak stress is ≤σ_s/2;
4) Apply surface hardening to raise strength;
5) Perform flaw detection;
6) Carry out fatigue grading;
7) Validate on the bench;
8) Include section transitions and fillets in the hydraulic cylinder design guidelines.

Checklist

References

GB/T 13342 Hydraulic Cylinders