E42-123 · Stress Concentration · Servo Electric Cylinder Screw · ★★
The screw fractured at the thread run-out relief groove
[Relief Groove Stress] The thread run-out relief groove radius R=0.5 is too sharp, giving a stress concentration Kt=3.0.
[Fracture] The alternating axial force drives the stress at the groove above the limit and it breaks.
[Design Omission] The relief groove had no fillet transition and the stress was not checked.
1) Change the relief groove to an R2 fillet transition;
2) Check the screw stress by finite element;
3) Use a standard thread run-out;
4) Strengthen the surface by roller burnishing;
5) Measure the axial force and limit it;
6) Perform flaw detection every 2000 running hours;
7) Upgrade the material to alloy steel;
8) Include the relief groove stress in the review.
GB/T 5796 Trapezoidal Screw Threads