Sharp Corner on Hydraulic-Cylinder Plug Causing Root Crack

E42-236 · Stress Concentration · Hydraulic Cylinder Plug · ★★★

Problem Description

During pressure test the plug root cracks and leaks; pressure cannot build.

Root Cause

[Plug Sharp Corner] Hex socket plug root R=0; stress concentration K_t=3.2; oil pressure p=25MPa. [Root Crack Leak] Under alternating pressure the root cracks and weeps. [Design Omission] Plug to standard minimum R, not strengthened.

Corrective Solution

1. Increase plug root R from 0 to R1.5.
2. Quench-and-temper plug in 35 steel.
3. Select upper-limit thread pitch diameter for locking.
4. Step pressure test to 1.5×.
5. Magnetic-particle inspection at root.
6. Sample-check R each batch.
7. Use copper gasket for sealing.