Knowledge Base › Structural Design Error Case Study › No Relief Groove at Shaft Shoulder Causing Stepped-Shaft Fatigue Fracture

No Relief Groove at Shaft Shoulder Causing Stepped-Shaft Fatigue Fracture

E42-174 · Stress Concentration · Reducer Input Shaft Φ50/Φ40 · ★★★

Problem Description

Fractures at the shaft shoulder; fracture surface shows fatigue striations.

Root Cause

[No Relief] Square shaft-shoulder transition; K_t=2.6. [Fatigue] Torsion σ=140MPa amplified to 364MPa fractures. [Design Omission] No relief groove R=2, no shot peening; 5 shafts fracture per year.

Corrective Solution

1. Set relief groove at shaft shoulder R≥2mm.
2. Change stepped shaft to tapered transition.
3. Roll-stress the shaft-shoulder fillet.
4. Surface quench to raise fatigue limit.
5. Lower torsional stress amplitude.
6. Balance the shaft.
7. Magnetic-particle inspection at fracture-prone locations.
8. Sample torsional fatigue each batch.

Checklist

Reference

GB/T 3075-2020