MOULDLKnowledge Base3D Model DownloadsMembership
中文版Model Store »
HomeModels
Table of contents

Knowledge Base Home

📐 Standard Data

🧮 Calculators

📖 Selection Guides

🏭 Material Grades

❓ Engineer FAQ

🗂 Quick-Reference Categories

❌ Error Case Studies

📚 Technical Articles

Knowledge Base › Structural Design Error Case Study › Un-Rounded Flange Root Cracking

Un-Rounded Flange Root Cracking

E42-239 · Stress Concentration · Flange Hub · ★★★

Problem Description

Flange root cracks and leaks under pressure.

Root Cause

[Root Sharp Corner] Hub-to-shell junction R=0; K_t=3; bending σ=160MPa. [Crack/Leak] Internal pressure cracks root; medium leaks. [Design Omission] No transition fillet; abrupt wall-thickness change.

Corrective Solution

1. Increase flange root R to R6.
2. Wall transition 1:3 taper.
3. One-piece forged.
4. Post-weld RT.
5. Hydrotest 1.5× pressure-hold.
6. Sample root NDT each batch.
7. FEA stress check.
8. Add stiffening ring on critical parts.

Checklist

Reference

GB/T 150.1-2011

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »