E42-176 · Thermal Deformation and Thermal Stress · Gantry Milling Machine Dual Guide Ways · ★★
Guide-way temp difference 5℃; guide error 0.02m/m.
[Temp Difference] One guide way sunlit; 5℃ difference between ways. [Error] Linear expansion difference ΔL=α·ΔT·L=0.06mm/m. [Design Omission] No cover; no equalization; guide error out of tolerance.
1. Add telescopic cover over guide ways for shade.
2. Symmetrically arrange dual ways to same heat source.
3. Set equalizing air curtain to reduce temp difference.
4. Place machine in constant-temp room 20±1℃.
5. Compensate guide error by temp difference.
6. Same guide-way material to lower α difference.
7. Preheat and equalize before run.
8. Re-measure guide error every 1h.
GB/T 17421.1-1998