Knowledge Base › Structural Design Error Case Study › Guide-Way Temperature Difference Causing Increased Guide Error

Guide-Way Temperature Difference Causing Increased Guide Error

E42-176 · Thermal Deformation and Thermal Stress · Gantry Milling Machine Dual Guide Ways · ★★

Problem Description

Guide-way temp difference 5℃; guide error 0.02m/m.

Root Cause

[Temp Difference] One guide way sunlit; 5℃ difference between ways. [Error] Linear expansion difference ΔL=α·ΔT·L=0.06mm/m. [Design Omission] No cover; no equalization; guide error out of tolerance.

Corrective Solution

1. Add telescopic cover over guide ways for shade.
2. Symmetrically arrange dual ways to same heat source.
3. Set equalizing air curtain to reduce temp difference.
4. Place machine in constant-temp room 20±1℃.
5. Compensate guide error by temp difference.
6. Same guide-way material to lower α difference.
7. Preheat and equalize before run.
8. Re-measure guide error every 1h.

Checklist

Reference

GB/T 17421.1-1998

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »