Asymmetric Long-Weld Sequence Causing Structural Side-Bow Distortion

E42-177 · Thermal Deformation and Thermal Stress · Large Welded Crosshead 6000mm · ★★

Problem Description

Post-weld crosshead side-bow 8mm over full length; straightness out of tolerance.

Root Cause

[Asymmetric Sequence] Weld one side full length first, then the other; longitudinal shrinkage asymmetric. [Side-Bow] Shrinkage difference ΔL=5mm causes 8mm/m side-bow. [Design Omission] No symmetric segmented welding; no preset distortion; straightening 6h/piece.

Corrective Solution

1. Define symmetric segmented skip-weld procedure.
2. Back-step weld from center outward.
3. Preset 5mm side-bow distortion before welding.
4. Rigid fixturing to prevent side-bow.
5. Symmetric multi-pass on long weld.
6. Control interpass temp ≤150℃.
7. Stress-relieve then straighten after welding.
8. CMM check full-length straightness.

Checklist

Reference

GB 50661-2011