E42-243 · Thermal Deformation and Thermal Stress · Hydraulic Power Unit · ★★★
After continuous operation, the oil temperature rose to 65℃, and the valve block joint surface leaked oil.
[Oil Temperature Rise] System efficiency η=0.7, losses converted to heat raised the oil temperature to 65℃. [Valve Block Deformation] The aluminum valve block expanded 0.05mm thermally, loosening the joint surface and causing leakage. [Design Omission] No cooler was provided and the valve block is made of aluminum.
1. Install an air-cooled radiator in the system.
2. Change the valve block to ductile iron to reduce expansion.
3. Control the oil temperature to ≤55℃.
4. Add copper gaskets at the joint surface.
5. Set up relief valve unloading.
6. Check the oil temperature every shift.
7. Retighten important joints.
8. Run a temperature-rise test before delivery.
GB/T 3766-2015