Knowledge Base › Structural Design Error Case Study › Guideway Thermal Bending Caused by Uneven Coolant on Guideway Grinder

Guideway Thermal Bending Caused by Uneven Coolant on Guideway Grinder

E42-292 · Thermal Deformation and Thermal Stress · Guideway Grinder · ★★

Problem Description

Coolant applied on one side of the guideway grinder, guideway temperature difference 8℃, thermal bending 0.04mm, convex machined surface; 2 units reworked per month

Root Cause

[Uneven] Single-side cooling, guideway temperature difference ΔT=8℃, expansion difference between upper and lower faces caused bending.
[Bending] Deflection f=α·L²·ΔT/(8h)≈0.04mm, machined surface convex in the middle.
[Design Omission] No uniform cooling and no thermal insulation; flatness is only IT8 (should be IT5).

Corrective Solution

1) Symmetrical cooling on both sides;
2) Constant-temperature oil tank supply (±1℃);
3) Add thermal insulation cover to the guideway;
4) Hot-state error compensation;
5) Measure temperature difference every shift;
6) Flow-equalizing valve to adjust flow rate;
7) Control ambient temperature ±2℃;
8) Re-measure flatness in hot state.

Checklist

Reference

GB/T 17421.2-2016

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »