E42-293 · Thermal Deformation and Thermal Stress · Machining Center · ★★
Machining center spindle motor housing temperature rose 30℃, bed temperature rose 6℃, geometric accuracy drifted; 3 units reworked per month
[Temperature Rise] Motor housing temperature rose 30℃, transferred through the support to the bed, raising it 6℃.
[Deformation] Bed thermal elongation 0.02mm, positioning drift exceeding the allowance.
[Design Omission] No thermal insulation and no compensation; geometric accuracy retention is only IT7 (should be IT5).
1) Add thermal insulation cover to the motor to break the heat path;
2) Independent cooling circuit;
3) Thermal error compensation;
4) Control ambient temperature ±2℃;
5) Measure temperature rise every shift;
6) Separate layout of heat sources;
7) Re-measure geometric accuracy in hot state;
8) Run in a constant-temperature room.
GB/T 17421.2-2016