E42-294 · Thermal Deformation and Thermal Stress · Hydraulic Oil Tank · ★★
Hydraulic oil tank temperature rose 20℃, tank wall expanded 0.015mm, joint surface leaked oil; 4 overhauls per month
[Oil Temperature Rise] Oil temperature rose 20℃, tank wall linear expansion δ=α·L·ΔT=12e-6×600×20=0.014mm.
[Leakage] Joint surface displacement exceeded gasket compensation, causing oil leakage.
[Design Omission] No heat dissipation and no seal compensation; oil temperature upper limit controlled only to 65℃ (should be ≤55℃).
1) Add a plate heat exchanger;
2) Temperature control valve limiting at 55℃;
3) Increase tank volume to reduce temperature rise;
4) Add ribs to flanges for higher stiffness;
5) Measure oil temperature every shift;
6) Seal compensation design (corrugated-tooth gasket);
7) Thermal insulation wrapping of the tank;
8) Regular leakage inspection.
GB/T 3766-2015