Knowledge Base › Structural Design Error Case Study › Overall Distortion Caused by Improper Welding Sequence of Welded Frame

Overall Distortion Caused by Improper Welding Sequence of Welded Frame

E42-295 · Thermal Deformation and Thermal Stress · Welded Frame · ★★

Problem Description

Improper welding sequence of welded frame, diagonal difference 5mm out of tolerance, overall distortion; 3 pieces reworked per month

Root Cause

[Wrong Sequence] Outer frame welded before inner ribs, uneven shrinkage produced torque.
[Distortion] Cumulative angular deformation made the diagonal difference 5mm (allowance 2mm).
[Design Omission] No process specification and no reverse deformation; form and position tolerance is only IT12 (should be IT10).

Corrective Solution

1) Symmetrical skip welding;
2) Weld inner ribs before outer frame;
3) Pre-set distortion compensation;
4) Rigidly fixed jig;
5) Measure diagonal ≤2mm after each sequence;
6) Anneal after welding;
7) Optimize welding sequence;
8) First-piece CMM.

Checklist

Reference

GB/T 19869.1-2005