Knowledge Base › Structural Design Error Case Study › Seizure Caused by Thermal Elongation of Injection Molding Machine Screw Barrel

Seizure Caused by Thermal Elongation of Injection Molding Machine Screw Barrel

E42-472 · Thermal Deformation and Thermal Stress · Injection Molding Machine Screw Barrel · ★★

Problem Description

Injection molding machine (800t) screw barrel thermally elongated 2.1mm and seized, jamming material; 2 repairs per month

Root Cause

[Thermal Elongation] Barrel temperature T=250℃, linear expansion ΔL=αLΔT=2.1mm.
[Seizure] No axial compensation caused seizure.
[Design Omission] No thermal expansion clearance and no compensation; safety factor 1.4 (should be ≥2.0).

Corrective Solution

1) Provide axial expansion joint;
2) Leave 2.5mm thermal expansion clearance;
3) Hollow screw cooling;
4) Barrel temperature control ±3℃;
5) Measure clearance every shift;
6) Limit material temperature;
7) Add thrust bearings;
8) Periodic re-measurement.

Checklist

Reference

GB/T 25156-2010