E42-473 · Thermal Deformation and Thermal Stress · Hot Strip Mill Housing · ★★
Hot strip mill housing thermally deformed 0.15mm, roll gap drifted out of tolerance; 3 coils scrapped per month
[Thermal Deformation] Housing temperature rise ΔT=35℃, expansion Δ=αLΔT=0.15mm, roll gap drifted.
[Drift] Screw-down accuracy lost.
[Design Omission] No cooling and no compensation; safety factor 1.4 (should be ≥2.0).
1) Water cooling through the housing;
2) Control temperature rise ≤15℃;
3) Roll gap thermal compensation;
4) Add guide columns;
5) Measure temperature every shift;
6) Limit rolling temperature;
7) Add ribs to the housing;
8) Periodic re-measurement.
GB/T 1184-1996