Knowledge Base › Structural Design Error Case Study › Tidal-Zone Corrosion of Offshore Platform Node

Tidal-Zone Corrosion of Offshore Platform Node

E42-435 · Corrosion Failure · Jacket node · ★★★

Problem Description

Jacket tidal-zone node (carbon steel): corrosion rate 0.4mm/a, wall thinned from 20mm to 14mm; treated annually

Root Cause

[Tidal-zone corrosion] Wet-dry cycling plus marine growth, local corrosion 0.4mm/a. [Thinning] Node wall thinned 6mm in 6 years. [Design Omission] No heavy corrosion protection, no sacrificial anode; safety factor 1.2 (should be ≥2.0).

Corrective Solution

1) Node heavy corrosion-protection coating plus anode;
2) Add 6mm corrosion allowance to wall thickness;
3) Change material to weathering steel;
4) Underwater inspection every 2 years;
5) Clean marine growth;
6) Add corrosion coupons;
7) Limit load;
8) Repair at end of life.

Checklist

Reference

GB/T 35990-2018