Absence of Overload Protection Leads to Plastic Buckling of the Lifting Beam

E42-033 · Impact & Overload Fracture · Lifting Beam · ★★★

Problem Symptom

The beam bent plastically and fractured under a 30% overload

Root Cause

[Overload Stress] The rated load is 50t but the actual load is 65t, so the bending moment M exceeds the rating by 30% and σ=1.3σ_allow=1.3×200=260, above σ_s=235.
[Plastic Behaviour] Exceeding the yield point (σ=260>σ_s=235), the beam deflects permanently and then fractures.
[Design Omission] No overload protection and no travel limit were provided, so the beam bent and broke.

Correct Solution

1) Add load weighing with automatic power cut-off on overload;
2) Mark the load limit conspicuously;
3) Check the beam for a 1.25 times dynamic factor;
4) Raise the safety factor to 1.5;
5) Provide mechanical travel limits;
6) Carry out regular point-by-point inspection;
7) Perform magnetic-particle inspection on critical beams;
8) Make overload protection a mandatory item in safety review.

Checklist

References

GB/T 3811 Code for Design of Cranes

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »