No Buffering on the Air Hammer Ram Causes Impact Bulging of the Rod

E42-081 · Impact & Overload Fracture · Air Hammer C41-400 · ★★★

Problem Symptom

The hammer rod bulges from the impact

Root Cause

[Impact Load] The blow energy is E=900J and the impact stress exceeds twice the yield strength.
[Bulging] Without buffering the hammer rod bulges plastically.
[Design Omission] No buffer was fitted and the rod diameter was too small, so the rod bulged.

Correct Solution

1) Add disc spring buffering to the hammer rod;
2) Increase the rod diameter to Φ60;
3) Upgrade the material;
4) Limit the blow energy;
5) Repair the guide sleeve;
6) Perform regular flaw detection;
7) Ensure the hammer head is in contact and aligned;
8) Include the impact check-up in the design.

Checklist

References

JB/T 1827-2013 Air Hammers

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL