E42-081 · Impact & Overload Fracture · Air Hammer C41-400 · ★★★
The hammer rod bulges from the impact
[Impact Load] The blow energy is E=900J and the impact stress exceeds twice the yield strength.
[Bulging] Without buffering the hammer rod bulges plastically.
[Design Omission] No buffer was fitted and the rod diameter was too small, so the rod bulged.
1) Add disc spring buffering to the hammer rod;
2) Increase the rod diameter to Φ60;
3) Upgrade the material;
4) Limit the blow energy;
5) Repair the guide sleeve;
6) Perform regular flaw detection;
7) Ensure the hammer head is in contact and aligned;
8) Include the impact check-up in the design.
JB/T 1827-2013 Air Hammers