Dynamic Load Factor Not Accounted for Causes Plastic Bending of the Lifting Hook

E42-083 · Impact & Overload Fracture · Lifting Hook 20 Steel · ★★★

Problem Symptom

The hook bent under the shock of lifting

Root Cause

[Impact Factor] The dynamic factor K=1.5 was not accounted for, but the actual value was 2 times.
[Plastic Bending] The stress exceeded the yield strength and the hook bent.
[Design Omission] Neither the dynamic factor nor the check-up was performed, so the hook bent.

Correct Solution

1) Check with a dynamic factor K=2;
2) Thicken the hook section;
3) Limit the lifting speed for smooth starts;
4) Upgrade the material;
5) Perform magnetic-particle inspection;
6) Mark the rated load;
7) Carry out regular load tests;
8) Include the dynamic load in the design.

Checklist

References

GB/T 10051.1-2010 Lifting Hooks